Product Specifications |
Battery of Analyzer |
|
Battery Backup Time (continuous duty) |
30
hour |
| Low Battery indication |
Yes |
| Chemistry of Rechargeable Battery |
Li-ion |
| Number of Spare Rechargeable Batteries
supplied with the instrument |
0 |
| Battery Voltage |
3.7
Volt |
| Power Source |
Rechargeable
Battery |
| Battery is BIS Approved |
Yes |
| BIS Registration number for Battery under CRS
of MeitY |
NA |
Display / Indicator / Storage / Interface |
|
Display Type |
TFT
LCD |
| Record Memory (Minimum) |
50000 |
| Display Size |
2.4
inch |
| If yes, Capable to display the geolocation of
test inspection / location |
NA |
| GPS |
No |
| Data Interface |
USB |
| Camera |
No |
| Record Entry |
Through
Alphanumeric Keyboard |
| Availability of audible beeper for over range,
low battery etc. |
Yes |
| If yes, Capable to capture the clear image of
test target |
Yes |
| Record Data Downloadable to PC |
Yes |
| Minimum Record Fields |
Full
Information as per the user's requirement such as Driver Name, Vehicle
number, inspector name, test report with time, date, geo-location, instrument
id etc. |
Environmental / Certification |
|
Name of the Lab and Address |
NA |
| Conformity to Dry Heat test at 50 degree C for
16 hours as per IS :9000 latest |
Yes |
| Test Report Number and Date |
NA |
| Conformity to Damp heat at 40 degree C - 95%
RH (cyclic test): two cycles of 16+8 hours as per IS: 9000 latest |
Yes |
| Conformity to Cold test at - 5 / -10 / - 15 /
-20 degree C (as applicable) for 4 hours as per IS: 9000 latest |
Yes |
| Availability of Test Reports from Central Govt
/ NABL approved / ILAC accredited Lab to prove conformity to the
specification |
Yes |
|
Operating Conditions |
|
|
Maximum Operating Temperature |
50
degree Celsius |
| Minimum Operating Temperature |
-10
degree Celsius |
| Relative Humidity Non-Condensing (%) |
80 |
Physical |
|
Size (mm x mm x mm) |
200
X 81 X 33 |
| Weight |
250
gram |
Printer |
|
Printer consists of Inbuilt Rechargeable
Battery, Paper for offence printouts, Charger |
Yes |
| Printer |
With |
| "Minimum number of printouts that can be
taken with single charge of the printer battery (Hint:- Minimum 60 prints, if
'With Printer' May indicate '0' if not applicable)" |
100 |
| Minimum number of printouts that can be taken
with the paper available with the Printer |
100 |
| Type of Printer |
Internal
Thermal Printer |
| BIS Registration number for Printer under CRS
of MeitY |
NA |
| Print Resolution (dpi) |
200 |
| Printer Battery is BIS Approved |
Yes |
| BIS Registration number for Printer Battery
under CRS of Meaty |
NA |
Statutory Requirements |
|
If yes, the equipment meets the
requirements of the applicable latest Central Motor Vehicle Rules and all
Govt notifications |
Yes |
| Immunity to RF interface, meets requirement as
per EN:5008-/1992(emission) and EN:50082-1:1997 (immunity) or equivalent |
Yes |
| The equipment can be used as an evidential
instrument for Traffic Law Enforcement, the instrument is handheld, portable
and easy to operate |
Yes |
Technology / Performance |
|
RoHS Compliant |
Yes |
| Sensor Technology |
Electrochemical
- Fuel Cell (alcohol specific) |
| Sampling modes |
Both
Active and Passive |
| Time required for re-calibration |
12
month |
| Sampling Error Detection |
Alarm
on wrong sampling |
| Barometric Pressure Range (hpa or millibar) |
600
millibar |
| Drift of the breath analyzer in 6 months
period (mg / 100 ml BAC) |
1 |
| Analytical Response Time (At '0' level of
Alcohol) |
3
second |
| Warm up Time (after putting on) |
10
second |
| Easily replaceable mouthpiece with Sputum Trap |
Yes |
| Shelf Life of Fuel Cell |
3
year |
| Sample Taking Duration |
3
second |
| Sampling Method |
Deep
Lung Exhalation Method |
| Measuring Range [mg / 100 ml BAC (Blood
Alcohol Concentration)] |
0
to 500 |
| Accuracy |
+/-
5 % or better |
| Analytical Response Time for positive result |
5
second |