LIGHT SOURCE
|
Light Source |
Tungsten Halogen Lamp |
|
Diffraction Grating (lines/mm) |
1200 |
|
Switching of Light Source |
Automatic |
|
Wavelength Setting And Scanning |
Mannual |
TYPE
|
Type of Spectrophotometer |
VISIBLE |
|
Type of Optical System |
Single Beam |
|
Monochromator Type |
Holographic Grating |
|
Detector Type |
Photodiode |
|
Spectral Bandwidth Type |
Fixed Bandwidth |
OPTICAL PERFORMANCE
|
Source Wavelength - Minimum |
320 nanometer |
|
Source Wavelength - Maximum |
1000 nanometer |
|
Resolution |
1 nanometer |
|
Wavelength Accuracy (+/-) |
1 nanometer |
|
Bandwidth (nm) |
2.0 |
|
If variable band width, Specify the
incremental step value(mm) |
NA |
|
Scanning Speed (nm/min) |
0 |
|
Focal length (mm) |
150 to 199 |
|
Photometric measurement modes |
Transmittance,Absorbance,Concentration
(Wavelength, time) |
|
Photometric Absorbance (Max) (Abs) (+/-) |
2 |
|
Photometric Absorbance Accuracy (Max) (+/-) |
0.5 |
|
Photometric Transmittance (Max) (+/-) |
100 percent |
|
Photometric Transmittance Accuracy (Max)
(+/-) |
0.5 percent |
|
Photometric Reflectance (Max) (+/-) |
0 percent |
|
Photometric Reflectance Accuracy (Max) (+/-) |
0 percent |
|
Stray Light Correction |
Automatic |
|
Baseline Correction |
N/A |
|
Display |
In-built display |
|
Display type |
LCD with Backlight |
|
Display Size |
2 inch |
|
Test result printing |
Through external printer |
|
If inbuilt printer, Type of printer |
N/A |
|
Suitable software for connecting PC &
Printer |
Yes |
|
Connectivity |
RS 232 |
|
Internal storage(GB) |
0 |
|
Sample switching/selection |
Manual |
|
Capacity of Sample holder / Sample Carousel |
4 |
|
Mximum Path Length of sample |
100 millimeter |
|
Number of Cuvettes supplied-inclusive in the
scope of supply |
10 |
|
Power Supply |
230 V ± 10, 50 Hz |
|
Spares and Consumables inclusive in the
scope of supply |
No |
|
List of Items and Quantity of each item
included in the offer |
- |
OPERATING CONDITIONS
|
Minimum Operating Temperature |
5 degree Celsius |
|
Maximum Operating Temperature |
35 degree Celsius |
|
Operating Humidity (RH) (%) at 40 degree C |
85 percent |
|
Availability of UL/CE Certification as per
EN 61010-1:2010 Safety requirements for electrical equipment for measurement,
control, and laboratory use General requirements |
Yes |
|
Conformance to EMC/EMI as per EN
61326-1:2013 Electrical equipment for measurement, control and laboratory use |
Yes |
|
Availability of Test Reports from Central
Govt / NABL approved / ILAC acredited lab to prove conformity to the
specification |
No |
|
If yes test report to furnished,to the buyer
on demand |
N/A |
|
Test Report number and date |
- |
|
Name and address of the Lab |
- |